Fuel Level Sensors




Typical Installation Fuel level Sensors, Typical Installation
Typical Application Fuel level Sensors, Typical Application
Fuelsense - Installed With Display Indicator For % Level In Diesel Tank Fuelsense – Installed With Display Indicator For % Level In Diesel Tank

Technical Specification

Housing

Aluminum

Sense electrode and Still Well

Aluminum / Stainless Steel

Probe length

150mm Min., up to 1500mm Max.

Nominal Supply Voltage

12 / 24 V DC

Supply Voltage range

10......30 V DC 0r 10...60V DC on request

Accuracy

+ - 1% FSD

Available Analog Outputs on request

1.5- 4.5 VDC or 1-5 VDC or1-10 VDC or 4-20 mA DC as per request

Available Digital Outputs on request

RS232 or RS485 as per request

Transient Voltage Protection

100 V max

Ambient temperature range

-20 to 85 ° C.

Warm up time after power on

< 10 Secs